CVE-2026-136548
validatedZero produced an exploit or a check.description
Tenda RX3 devices running version 16.03.13.11 are affected by a stack-based buffer overflow in the auto_discover GBK-to-UTF-8 conversion path. An attacker able to remotely reach the affected functionality may be able to trigger the overflow through hostname handling.
mitigation
Restrict network access to affected RX3 devices and isolate them from untrusted networks, allowing only trusted hosts to reach discovery-related functionality. No fixed version is recorded; monitor vendor updates and upgrade promptly when a corrected release is available.
outcome
Contextual check: a technique exists and was validated, but no deterministic check could cover this one.
source signals
Public signals that triggered or updated the pipeline. These are inputs for the deltas above.
- 2026-11-25 05:15Zcve_org: trigger signal, started the run
- 2026-11-25 05:41Zexploit reference (github.com)
this entry in the feed
GET /api/v1/feed/CVE-2026-136548
{ "etk_id": "ETK-2026-5452", "cve_id": "CVE-2026-136548", "display_id": "CVE-2026-136548", "ghsa_id": null, "euvd_id": "EUVD-2026-134992", "status": "published", "anchor_state": "anchored", "title": "Stack-based buffer overflow in Tenda RX3 auto_discover", "summary": "Tenda RX3 devices running version 16.03.13.11 are affected by a stack-based buffer overflow in the auto_discover GBK-to-UTF-8 conversion path. An attacker able to remotely reach the affected functionality may be able to trigger the overflow through hostname handling.", "mitigation": "Restrict network access to affected RX3 devices and isolate them from untrusted networks, allowing only trusted hosts to reach discovery-related functionality. No fixed version is recorded; monitor vendor updates and upgrade promptly when a corrected release is available.", "vendor": "Tenda", "product": "RX3", "affected": [ { "affected_notes": [], "affected_ranges": [ "16.03.13.11" ], "ecosystem": null, "fixed_versions": [], "package_name": "RX3", "purl": null } ], "cwes": [ 121 ], "cvss_score": 10, "cvss_src": "cna_vendor", "cvss_vector": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P", "epss_score": null, "epss_percentile": null, "epss_asof": null, "automation": "contextual", "check": true, "check_confidence_basis": "assessed", "exploit": false, "pipeline_minutes": 15.038737466666667, "t0_at": "2026-11-25T05:15:17.187000+00:00", "signals": { "check": { "at": "2026-11-25T05:43:03.090073+00:00", "days": 0.01928128556712963, "is_lower_bound": false, "measured_at": "2026-11-25T05:15:17.187000+00:00", "url": null }, "public_poc": { "at": "2026-11-25T05:15:17.187000+00:00", "days": 0, "is_lower_bound": false, "measured_at": "2026-11-25T05:15:17.187000+00:00", "url": "https://github.com/Zeyfrost/tenda-rx3-vulns/blob/master/dhcp_gbk_overflow/detail.md" }, "trigger_signal": { "at": "2026-11-25T05:15:17.187000+00:00", "days": 0, "is_lower_bound": false, "measured_at": "2026-11-25T05:15:17.187000+00:00", "url": "https://www.cve.org/CVERecord?id=CVE-2026-136548" } } }
published 2026-11-25 05:27Z
last change 2026-11-25 06:08Z
Need the technical details behind an entry?
Every entry here shows what we attempted and when. The technical details, the generated exploit that fired it and the evidence behind the verdict are not public. Tell us about your use case and we’ll get back to you about extended API access.