CVE-2026-135788
waiting for further signalsZero needs more public information before it can validate it.GHSA-g5wr-chm9-xp2w ↗EUVD-2026-134180 ↗
description
D-Link DIR-X1860 devices running firmware 4.5.2 are affected by an OS command injection issue in the anweb component. A remote attacker with the necessary access privileges may be able to execute commands on the device.
mitigation
Restrict router management access to trusted administrative networks and disable Internet-facing administration. Apply vendor firmware updates when a corrected release is published; no fixed version is recorded in the advisory.
outcome
Contextual, not validated: no deterministic check could cover this one, and no technique passed our review.
source signals
Public signals that triggered or updated the pipeline. These are inputs for the deltas above.
- 2026-11-24 16:15Zcve_org: trigger signal, started the run
- 2026-11-24 17:04Zexploit reference (github.com)
this entry in the feed
GET /api/v1/feed/CVE-2026-135788
{ "etk_id": "ETK-2026-5390", "cve_id": "CVE-2026-135788", "display_id": "CVE-2026-135788", "ghsa_id": "GHSA-g5wr-chm9-xp2w", "euvd_id": "EUVD-2026-134180", "status": "published", "anchor_state": "anchored", "title": "OS command injection in D-Link DIR-X1860 anweb", "summary": "D-Link DIR-X1860 devices running firmware 4.5.2 are affected by an OS command injection issue in the anweb component. A remote attacker with the necessary access privileges may be able to execute commands on the device.", "mitigation": "Restrict router management access to trusted administrative networks and disable Internet-facing administration. Apply vendor firmware updates when a corrected release is published; no fixed version is recorded in the advisory.", "vendor": "D-Link", "product": "DIR-X1860", "affected": [ { "affected_notes": [], "affected_ranges": [ "4.5.2" ], "ecosystem": null, "fixed_versions": [], "package_name": "DIR-X1860", "purl": null } ], "cwes": [ 78 ], "cvss_score": 9.4, "cvss_src": "cna_vendor", "cvss_vector": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P", "epss_score": null, "epss_percentile": null, "epss_asof": null, "automation": "contextual", "check": false, "check_confidence_basis": null, "exploit": false, "pipeline_minutes": 6.56992825, "t0_at": "2026-11-24T16:15:12.548000+00:00", "signals": { "public_poc": { "at": "2026-11-24T16:15:12.548000+00:00", "days": 0, "is_lower_bound": false, "measured_at": "2026-11-24T16:15:12.548000+00:00", "url": "https://github.com/nenghun/IoT/blob/main/D-Link%20DIR%20X1860/D-Link%20DIR-X1860%204.5.2%20rce.md" }, "trigger_signal": { "at": "2026-11-24T16:15:12.548000+00:00", "days": 0, "is_lower_bound": false, "measured_at": "2026-11-24T16:15:12.548000+00:00", "url": "https://www.cve.org/CVERecord?id=CVE-2026-135788" } } }
published 2026-11-24 16:43Z
last change 2026-11-25 00:30Z
Need the technical details behind an entry?
Every entry here shows what we attempted and when. The technical details, the generated exploit that fired it and the evidence behind the verdict are not public. Tell us about your use case and we’ll get back to you about extended API access.