CVE-2026-116783
waiting for further signalsZero needs more public information before it can validate it.GHSA-mjp3-3cq2-hxj4 ↗EUVD-2026-117759 ↗
description
FreeSWITCH versions before 1.11.2 are affected by an out-of-bounds write in mod_spandsp T.38 UDPTL processing. A peer able to send UDPTL to an established T.38 fax session can cause memory corruption and crash FreeSWITCH, ending active calls. Deployments using T.38 fax applications or gateways are exposed when such a peer can reach the session.
mitigation
Upgrade FreeSWITCH to version 1.11.2 or later. Until upgraded, restrict untrusted peers from reaching established T.38 UDPTL sessions and disable or limit T.38 fax services where feasible.
fixed in >= 1.11.2
outcome
Contextual, not validated: no deterministic check could cover this one, and no technique passed our review.
source signals
Public signals that triggered or updated the pipeline. These are inputs for the deltas above.
- 2026-11-05 19:41Zcve_org: trigger signal, started the run
this entry in the feed
GET /api/v1/feed/CVE-2026-116783
{ "etk_id": "ETK-2026-3665", "cve_id": "CVE-2026-116783", "display_id": "CVE-2026-116783", "ghsa_id": "GHSA-mjp3-3cq2-hxj4", "euvd_id": "EUVD-2026-117759", "status": "published", "anchor_state": "anchored", "title": "Out-of-bounds write in FreeSWITCH mod_spandsp", "summary": "FreeSWITCH versions before 1.11.2 are affected by an out-of-bounds write in mod_spandsp T.38 UDPTL processing. A peer able to send UDPTL to an established T.38 fax session can cause memory corruption and crash FreeSWITCH, ending active calls. Deployments using T.38 fax applications or gateways are exposed when such a peer can reach the session.", "mitigation": "Upgrade FreeSWITCH to version 1.11.2 or later. Until upgraded, restrict untrusted peers from reaching established T.38 UDPTL sessions and disable or limit T.38 fax services where feasible.", "vendor": "signalwire", "product": "freeswitch", "affected": [ { "affected_notes": [], "affected_ranges": [ "<= 1.11.1" ], "ecosystem": "c", "fixed_versions": [ ">= 1.11.2" ], "package_name": "FreeSWITCH", "purl": null } ], "cwes": [ 129 ], "cvss_score": 8.2, "cvss_src": "cna_vendor", "cvss_vector": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H", "epss_score": null, "epss_percentile": null, "epss_asof": null, "automation": "contextual", "check": false, "check_confidence_basis": null, "exploit": false, "pipeline_minutes": 16.166834, "t0_at": "2026-11-05T19:41:44.761000+00:00", "signals": { "trigger_signal": { "at": "2026-11-05T19:41:44.761000+00:00", "days": 0, "is_lower_bound": false, "measured_at": "2026-11-05T19:41:44.761000+00:00", "url": "https://www.cve.org/CVERecord?id=CVE-2026-116783" } } }
published 2026-11-05 21:00Z
last change 2026-11-05 22:14Z
Need the technical details behind an entry?
Every entry here shows what we attempted and when. The technical details, the generated exploit that fired it and the evidence behind the verdict are not public. Tell us about your use case and we’ll get back to you about extended API access.