CVE-2026-116570
validatedZero produced an exploit or a check.GHSA-294g-hq4w-c275 ↗EUVD-2026-117738 ↗
description
FreeSWITCH before 1.11.2 has a stack buffer overflow in mod_xml_rpc HTTP directory authentication. An unauthenticated network client can crash the FreeSWITCH process and interrupt active calls when the module is exposed and a directory account has a sufficiently long configured credential.
mitigation
Upgrade FreeSWITCH to >= 1.11.2 or later.
fixed in >= 1.11.2
outcome
Contextual check: a technique exists and was validated, but no deterministic check could cover this one.
source signals
Public signals that triggered or updated the pipeline. These are inputs for the deltas above.
- 2026-11-05 19:21Zghsa: trigger signal, started the run
- 2026-11-05 19:21Zcve.org record for CVE-2026-116570
this entry in the feed
GET /api/v1/feed/CVE-2026-116570
{ "etk_id": "ETK-2026-5454", "cve_id": "CVE-2026-116570", "display_id": "CVE-2026-116570", "ghsa_id": "GHSA-294g-hq4w-c275", "euvd_id": "EUVD-2026-117738", "status": "published", "anchor_state": "anchored", "title": "Stack buffer overflow in FreeSWITCH mod_xml_rpc authentication", "summary": "FreeSWITCH before 1.11.2 has a stack buffer overflow in mod_xml_rpc HTTP directory authentication. An unauthenticated network client can crash the FreeSWITCH process and interrupt active calls when the module is exposed and a directory account has a sufficiently long configured credential.", "mitigation": "Upgrade FreeSWITCH to >= 1.11.2 or later.", "vendor": "freeswitch", "product": "freeswitch", "affected": [ { "affected_notes": [], "affected_ranges": [ "<= 1.11.1" ], "ecosystem": "c", "fixed_versions": [ ">= 1.11.2" ], "package_name": "FreeSWITCH", "purl": null } ], "cwes": [ 121 ], "cvss_score": 7.5, "cvss_src": "cna_vendor", "cvss_vector": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "epss_score": 0.0099, "epss_percentile": 0.6149, "epss_asof": "2026-11-25", "automation": "contextual", "check": true, "check_confidence_basis": "assessed", "exploit": false, "pipeline_minutes": 13.637436466666667, "t0_at": "2026-11-05T19:21:30.904000+00:00", "signals": { "check": { "at": "2026-11-25T05:54:47.732521+00:00", "days": 19.439778107881946, "is_lower_bound": false, "measured_at": "2026-11-05T19:21:30.904000+00:00", "url": null }, "trigger_signal": { "at": "2026-11-05T19:21:30.904000+00:00", "days": 0, "is_lower_bound": false, "measured_at": "2026-11-05T19:21:30.904000+00:00", "url": "https://github.com/signalwire/freeswitch/security/advisories/GHSA-294g-hq4w-c275" } } }
published 2026-11-25 05:41Z
last change 2026-11-26 05:24Z
Need the technical details behind an entry?
Every entry here shows what we attempted and when. The technical details, the generated exploit that fired it and the evidence behind the verdict are not public. Tell us about your use case and we’ll get back to you about extended API access.