CVE-2026-116448

waiting for further signalsZero needs more public information before it can validate it.

GHSA-37vr-jg2r-g6jg ↗EUVD-2026-128929 ↗

no check availablenot proven exploitable
cve.orgpublic pocExploit code has been published by someone. Source signals can also carry a PoC (Proof of Concept).kevAttacks confirmed in the real world.
Dell PowerStore 500T >= 0, < 5.1.0.0-2798105 or later
fixed in 5.1.0.0-2798105 or later
CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
ETK-2026-4807Zero's internal tracking ID, independent of the CVE number., permanent identifier
5h 59msince last run
9mAI analysisAnalysis: how long the AI spent reversing this signal.
timeline
0 = trigger signal
trigger signal (cve.org) +0hwaiting for further signals+1h19m
0
+2h
+4h
+6h
+8h
+10h
+12h

description

Dell PowerStore systems with SDNAS on affected versions are vulnerable to OS command injection. An attacker with access to the internal network could run commands with root privileges on the NAS node.

mitigation

Upgrade affected PowerStore appliances to version 5.1.0.0-2798105 or later. Restrict internal network access to PowerStore management and NAS-related interfaces until upgrades are complete.

fixed in 5.1.0.0-2798105 or later

check
no
exploit
no
automationDeterministic: a check that runs on its own, the same request on every target. Contextual: an agentic technique that needs to be applied per target, for bugs that depend on contextual flows.
contextual
auth requiredWhether an attacker needs an account first, based on the CVSS vector's Privileges Required.
no
EPSSEstimate of the chance this CVE is exploited in the next 30 days. Refreshed daily.
–
agent run time
9m
cve.org record, t = 0The moment cve.org publishes the CVE in full.
2026-11-18 14:35Z
Δ to public pocExploit code has been published by someone. Source signals can also carry a PoC (Proof of Concept).
–
Δ to kevAttacks confirmed in the real world.
–

outcome

Contextual, not validated: no deterministic check could cover this one, and no technique passed our review.

source signals

Public signals that triggered or updated the pipeline. These are inputs for the deltas above.

  1. 2026-11-18 14:35Z
    cve_org: trigger signal, started the run

this entry in the feed

GET /api/v1/feed/CVE-2026-116448

{
  "etk_id": "ETK-2026-4807",
  "cve_id": "CVE-2026-116448",
  "display_id": "CVE-2026-116448",
  "ghsa_id": "GHSA-37vr-jg2r-g6jg",
  "euvd_id": "EUVD-2026-128929",
  "status": "published",
  "anchor_state": "anchored",
  "title": "OS command injection in Dell PowerStore SDNAS",
  "summary": "Dell PowerStore systems with SDNAS on affected versions are vulnerable to OS command injection. An attacker with access to the internal network could run commands with root privileges on the NAS node.",
  "mitigation": "Upgrade affected PowerStore appliances to version 5.1.0.0-2798105 or later. Restrict internal network access to PowerStore management and NAS-related interfaces until upgrades are complete.",
  "vendor": "Dell",
  "product": "PowerStore 500T",
  "affected": [
    {
      "affected_notes": [
        ">= 0, < 5.1.0.0-2798105 or later"
      ],
      "affected_ranges": [],
      "ecosystem": null,
      "fixed_versions": [
        "5.1.0.0-2798105 or later"
      ],
      "package_name": "PowerStore 500T",
      "purl": null
    },
    {
      "affected_notes": [
        ">= 0, < 5.1.0.0-2798105 or later"
      ],
      "affected_ranges": [],
      "ecosystem": null,
      "fixed_versions": [
        "5.1.0.0-2798105 or later"
      ],
      "package_name": "PowerStore 1000T",
      "purl": null
    },
    {
      "affected_notes": [
        ">= 0, < 5.1.0.0-2798105 or later"
      ],
      "affected_ranges": [],
      "ecosystem": null,
      "fixed_versions": [
        "5.1.0.0-2798105 or later"
      ],
      "package_name": "PowerStore 1200T",
      "purl": null
    },
    {
      "affected_notes": [
        ">= 0, < 5.1.0.0-2798105 or later"
      ],
      "affected_ranges": [],
      "ecosystem": null,
      "fixed_versions": [
        "5.1.0.0-2798105 or later"
      ],
      "package_name": "PowerStore 3000T",
      "purl": null
    },
    {
      "affected_notes": [
        ">= 0, < 5.1.0.0-2798105 or later"
      ],
      "affected_ranges": [],
      "ecosystem": null,
      "fixed_versions": [
        "5.1.0.0-2798105 or later"
      ],
      "package_name": "PowerStore 3200Q",
      "purl": null
    },
    {
      "affected_notes": [
        ">= 0, < 5.1.0.0-2798105 or later"
      ],
      "affected_ranges": [],
      "ecosystem": null,
      "fixed_versions": [
        "5.1.0.0-2798105 or later"
      ],
      "package_name": "PowerStore 3200T",
      "purl": null
    },
    {
      "affected_notes": [
        ">= 0, < 5.1.0.0-2798105 or later"
      ],
      "affected_ranges": [],
      "ecosystem": null,
      "fixed_versions": [
        "5.1.0.0-2798105 or later"
      ],
      "package_name": "PowerStore 5000T",
      "purl": null
    },
    {
      "affected_notes": [
        ">= 0, < 5.1.0.0-2798105 or later"
      ],
      "affected_ranges": [],
      "ecosystem": null,
      "fixed_versions": [
        "5.1.0.0-2798105 or later"
      ],
      "package_name": "PowerStore 5200Q",
      "purl": null
    },
    {
      "affected_notes": [
        ">= 0, < 5.1.0.0-2798105 or later"
      ],
      "affected_ranges": [],
      "ecosystem": null,
      "fixed_versions": [
        "5.1.0.0-2798105 or later"
      ],
      "package_name": "PowerStore 5200T",
      "purl": null
    },
    {
      "affected_notes": [
        ">= 0, < 5.1.0.0-2798105 or later"
      ],
      "affected_ranges": [],
      "ecosystem": null,
      "fixed_versions": [
        "5.1.0.0-2798105 or later"
      ],
      "package_name": "PowerStore 7000T",
      "purl": null
    },
    {
      "affected_notes": [
        ">= 0, < 5.1.0.0-2798105 or later"
      ],
      "affected_ranges": [],
      "ecosystem": null,
      "fixed_versions": [
        "5.1.0.0-2798105 or later"
      ],
      "package_name": "PowerStore 9000T",
      "purl": null
    },
    {
      "affected_notes": [
        ">= 0, < 5.1.0.0-2798105 or later"
      ],
      "affected_ranges": [],
      "ecosystem": null,
      "fixed_versions": [
        "5.1.0.0-2798105 or later"
      ],
      "package_name": "PowerStore 9200T",
      "purl": null
    },
    {
      "affected_notes": [
        ">= 0, < 5.1.0.0-2798105 or later"
      ],
      "affected_ranges": [],
      "ecosystem": null,
      "fixed_versions": [
        "5.1.0.0-2798105 or later"
      ],
      "package_name": "PowerStore 1500",
      "purl": null
    },
    {
      "affected_notes": [
        ">= 0, < 5.1.0.0-2798105 or later"
      ],
      "affected_ranges": [],
      "ecosystem": null,
      "fixed_versions": [
        "5.1.0.0-2798105 or later"
      ],
      "package_name": "PowerStore 5500",
      "purl": null
    },
    {
      "affected_notes": [
        ">= 0, < 5.1.0.0-2798105 or later"
      ],
      "affected_ranges": [],
      "ecosystem": null,
      "fixed_versions": [
        "5.1.0.0-2798105 or later"
      ],
      "package_name": "PowerStore 9500",
      "purl": null
    }
  ],
  "cwes": [
    78
  ],
  "cvss_score": 9.8,
  "cvss_src": "cna_vendor",
  "cvss_vector": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
  "epss_score": null,
  "epss_percentile": null,
  "epss_asof": null,
  "automation": "contextual",
  "check": false,
  "check_confidence_basis": null,
  "exploit": false,
  "pipeline_minutes": 9.01966955,
  "t0_at": "2026-11-18T14:35:35.043000+00:00",
  "signals": {
    "trigger_signal": {
      "at": "2026-11-18T14:35:35.043000+00:00",
      "days": 0,
      "is_lower_bound": false,
      "measured_at": "2026-11-18T14:35:35.043000+00:00",
      "url": "https://www.cve.org/CVERecord?id=CVE-2026-116448"
    }
  }
}

published 2026-11-18 14:44Z
last change 2026-11-18 20:42Z

Need the technical details behind an entry?

Every entry here shows what we attempted and when. The technical details, the generated exploit that fired it and the evidence behind the verdict are not public. Tell us about your use case and we’ll get back to you about extended API access.