CVE-2026-113364
validatedZero produced an exploit or a check.GHSA-9cm3-cgv8-62mc ↗EUVD-2026-119798 ↗
description
WebSAM WinShare on Windows is affected in versions 7.5.0 and earlier, 7.6.0, and 7.7.0 through 7.7.2. An unauthenticated remote attacker may execute code as SYSTEM by sending malformed protocol traffic to the data-receiving service. Exposure requires that an attacker can reach the affected service over the network.
mitigation
Restrict network access to the WebSAM WinShare data-receiving service to trusted hosts, such as by firewall allowlisting or network segmentation. Apply vendor-provided updates when available; the supplied advisory data does not identify a fixed version.
outcome
Contextual check: a technique exists and was validated, but no deterministic check could cover this one.
source signals
Public signals that triggered or updated the pipeline. These are inputs for the deltas above.
- 2026-11-09 04:14Zcve_org: trigger signal, started the run
this entry in the feed
GET /api/v1/feed/CVE-2026-113364
{ "etk_id": "ETK-2026-3929", "cve_id": "CVE-2026-113364", "display_id": "CVE-2026-113364", "ghsa_id": "GHSA-9cm3-cgv8-62mc", "euvd_id": "EUVD-2026-119798", "status": "published", "anchor_state": "anchored", "title": "Unauthenticated buffer overflow in WebSAM WinShare", "summary": "WebSAM WinShare on Windows is affected in versions 7.5.0 and earlier, 7.6.0, and 7.7.0 through 7.7.2. An unauthenticated remote attacker may execute code as SYSTEM by sending malformed protocol traffic to the data-receiving service. Exposure requires that an attacker can reach the affected service over the network.", "mitigation": "Restrict network access to the WebSAM WinShare data-receiving service to trusted hosts, such as by firewall allowlisting or network segmentation. Apply vendor-provided updates when available; the supplied advisory data does not identify a fixed version.", "vendor": "NEC Corporation", "product": "WebSAM WinShare", "affected": [ { "affected_notes": [ "Ver 7.5.0 and earlier", "Ver 7.6.0 and Ver 7.7.0 through 7.7.2" ], "affected_ranges": [], "ecosystem": null, "fixed_versions": [], "package_name": "WebSAM WinShare", "purl": null } ], "cwes": [ 122 ], "cvss_score": 9.3, "cvss_src": "cna_vendor", "cvss_vector": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "epss_score": 0.0076, "epss_percentile": 0.5561, "epss_asof": "2026-11-09", "automation": "contextual", "check": true, "check_confidence_basis": "assessed", "exploit": false, "pipeline_minutes": 7.923148183333334, "t0_at": "2026-11-09T04:14:03.038000+00:00", "signals": { "check": { "at": "2026-11-10T07:26:19.116679+00:00", "days": 1.1335194291550925, "is_lower_bound": false, "measured_at": "2026-11-09T04:14:03.038000+00:00", "url": null }, "trigger_signal": { "at": "2026-11-09T04:14:03.038000+00:00", "days": 0, "is_lower_bound": false, "measured_at": "2026-11-09T04:14:03.038000+00:00", "url": "https://www.cve.org/CVERecord?id=CVE-2026-113364" } } }
published 2026-11-09 04:25Z
last change 2026-11-11 05:00Z
Need the technical details behind an entry?
Every entry here shows what we attempted and when. The technical details, the generated exploit that fired it and the evidence behind the verdict are not public. Tell us about your use case and we’ll get back to you about extended API access.