CVE-2026-105778

waiting for further signalsZero needs more public information before it can validate it.

GHSA-pmv4-xrcq-cmxf ↗EUVD-2026-92987 ↗

no check availablenot proven exploitable
cve.orgpublic pocExploit code has been published by someone. Source signals can also carry a PoC (Proof of Concept).kevAttacks confirmed in the real world.
tenda AC5 02.03.01.111_multi
ETK-2026-754, permanent identifier
9d 23h 21msince last run
14mAI analysisAnalysis: how long the AI spent reversing this signal.
timeline
0 = trigger signal
trigger signal (cve.org) +0hwaiting for further signals+126h10m
0
+2h
+4h
+6h
+8h
+10h

description

Tenda AC5 devices running firmware 02.03.01.111_multi are affected by a stack-based buffer overflow in the Wi-Fi configuration handler. A remote attacker able to reach the management interface and provide the affected setting may be able to trigger the flaw.

mitigation

Disable remote administration and limit access to the device management interface to trusted administrative networks. Isolate affected devices from untrusted networks until Tenda provides a corrected firmware release.

check
no
exploit
no
automationDeterministic: a check that runs on its own, the same request on every target. Contextual: an agentic technique that needs to be applied per target, for bugs that depend on contextual flows.
contextual
auth requiredWhether an attacker needs an account first, based on the CVSS vector's Privileges Required.
yes, low privileges
EPSSEstimate of the chance this CVE is exploited in the next 30 days. Refreshed daily.
0.48%39th percentile
agent run time
14m
cve.org record, t = 0The moment cve.org publishes the CVE in full.
2026-10-06 06:45Z
Δ to public pocExploit code has been published by someone. Source signals can also carry a PoC (Proof of Concept).
–
Δ to kevAttacks confirmed in the real world.
–

outcome

Contextual: an exploit technique exists, but no deterministic check could cover this one.

source signals

Public signals that triggered or updated the pipeline. These are inputs for the deltas above.

  1. 2026-10-06 06:45Z
    ghsa: trigger signal, started the run
  2. 2026-10-06 06:45Z

this entry in the feed

GET /api/v1/feed/CVE-2026-105778

{
  "etk_id": "ETK-2026-754",
  "cve_id": "CVE-2026-105778",
  "display_id": "CVE-2026-105778",
  "ghsa_id": "GHSA-pmv4-xrcq-cmxf",
  "euvd_id": "EUVD-2026-92987",
  "status": "published",
  "anchor_state": "anchored",
  "title": "Stack-based buffer overflow in Tenda AC5 Wi-Fi handler",
  "summary": "Tenda AC5 devices running firmware 02.03.01.111_multi are affected by a stack-based buffer overflow in the Wi-Fi configuration handler. A remote attacker able to reach the management interface and provide the affected setting may be able to trigger the flaw.",
  "mitigation": "Disable remote administration and limit access to the device management interface to trusted administrative networks. Isolate affected devices from untrusted networks until Tenda provides a corrected firmware release.",
  "vendor": "tenda",
  "product": "AC5",
  "affected": [
    {
      "affected_notes": [],
      "affected_ranges": [
        "02.03.01.111_multi"
      ],
      "ecosystem": null,
      "fixed_versions": [],
      "package_name": "AC5",
      "purl": null
    }
  ],
  "cwes": null,
  "cvss_score": 9.9,
  "cvss_src": "cna_vendor",
  "cvss_vector": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
  "epss_score": 0.0048,
  "epss_percentile": 0.3984,
  "epss_asof": "2026-10-20",
  "automation": "contextual",
  "check": false,
  "check_confidence_basis": null,
  "exploit": false,
  "pipeline_minutes": 14.022595316666667,
  "t0_at": "2026-10-06T06:45:13.774000+00:00",
  "signals": {
    "trigger_signal": {
      "at": "2026-10-06T06:45:13.774000+00:00",
      "days": 0,
      "is_lower_bound": false,
      "measured_at": "2026-10-06T06:45:13.774000+00:00",
      "url": "https://github.com/advisories/GHSA-pmv4-xrcq-cmxf"
    }
  }
}

published 2026-10-06 10:39Z